WST9000/9100/9200 Series Open Loop Vector Drives
Description
Review
Description
Winston single phase Variable-frequency drive frequency converter inverter
Technical parameter
1. standard functions maximum frequency
2. Carrier frequency 0.5-16kHz the carrier frequency is automatically adjusted based on the load features.
3. Input frequency resolution: digital setting 0.01Hz,
2. Carrier frequency 0.5-16kHz the carrier frequency is automatically adjusted based on the load features.
3. Input frequency resolution: digital setting 0.01Hz,
Analog setting: maximum frequency 0.025%.
4. Control mode: V/F control
5. Startup torque: 150%
6. Speed range: 1:50
7. Speed stability accuracy: 1%
8. Overload capacity: G type :60s for 150% of the rated current,
4. Control mode: V/F control
5. Startup torque: 150%
6. Speed range: 1:50
7. Speed stability accuracy: 1%
8. Overload capacity: G type :60s for 150% of the rated current,
P type:60s for 130% of the rated current.
9. Torque boost: fixed boost,Customized boost 0.1%-30.0%
10. V/F curve: straight_line V/F curve,multi_point V/F curve,Square V/F curve
11. Ramp mode: straight_line ramp,S_curve ramp two groups of acceleration /deceleration time with the range of 0.00-300.0s(m)
12. DC braking:
9. Torque boost: fixed boost,Customized boost 0.1%-30.0%
10. V/F curve: straight_line V/F curve,multi_point V/F curve,Square V/F curve
11. Ramp mode: straight_line ramp,S_curve ramp two groups of acceleration /deceleration time with the range of 0.00-300.0s(m)
12. DC braking:
DC braking frequency:0.00Hz to maximum frequency ,
braking time: 0.0-36.0s,
braking action current value:0.0%-100.0%
13. JOG control:
13. JOG control:
JOG frequency range:0.00Hz to maximum frequency JOG acceleration/deceleration time 0.00-300.0s
14. Simple PLC,multi_speed running: it implements up to 8 speeds via the simple PLC function or combination of DI terminal states
15. Built_in PID: it implements the closed_loop process control system easily.
16. Auto voltage regulation(AVR): it can keep constant of output voltage automatically when the mains voltage changes.
17. Over current stall control: the current is limited automatically during the running so as to avoid frequency tripping due to over current.
18. Rapid current limit: it decreases the over current faults to the and ensures normal running of theAC drive.
14. Simple PLC,multi_speed running: it implements up to 8 speeds via the simple PLC function or combination of DI terminal states
15. Built_in PID: it implements the closed_loop process control system easily.
16. Auto voltage regulation(AVR): it can keep constant of output voltage automatically when the mains voltage changes.
17. Over current stall control: the current is limited automatically during the running so as to avoid frequency tripping due to over current.
18. Rapid current limit: it decreases the over current faults to the and ensures normal running of theAC drive.
Application
1. Wire drawing machines,industrial washing machines
2. Fluid machinery:Fan water pump,blower,music fountain.
3. Paper_making equipment,chemical industry
4. Pharmaceutical industry,textile industry
5. Public mechanical equipment,such as precision CNC machine tools etc.
2. Fluid machinery:Fan water pump,blower,music fountain.
3. Paper_making equipment,chemical industry
4. Pharmaceutical industry,textile industry
5. Public mechanical equipment,such as precision CNC machine tools etc.
Model Explanation
Keypad Description
Dimension
Wiring diagram
Packaging & Shipping
Review
Review
Send your message to us